หน้าหลัก ผลิตภัณฑ์

|VITROS® ECiQ

Immunology

Ortho VITROS® Chemistry, Immunoassay, and Integrated systems reduce potential for error and the need for repeat testing to increase first pass yield, decrease costs, and improve turnaround time.

Key differentiators:

  • VITROS® Systems do not require water, reducing costs and waste disposal while remaining environmentally friendly.
  • 96.5% first pass yield (delivering results without user intervention) – the highest in the industry.
  • VITROS® XT Solutions have an up to 25% faster turnaround time* for common test panels compared to competitive systems.
  • Low sample volume per test (2-80 µl).
  • New VITROS® XT analyzers deliver up to 40% higher throughput for greater lab efficiency.
  • Comprehensive testing menu including SARS-CoV-2 IgG and Total antibody, HIV combo, B·R·A·H·M·S Procalcitonin, Immunosuppressive drugs, and Drugs of abuse.

*TAT to complete the panel of these tests: Glucose, Calcium, Albumin, Total Protein, Sodium, Potassium, CO2, Chloride, BUN, Creatinine, ALP, ALT, AST, Bilirubin.

 


Specifications

 

Dimensions W x D x H 111.8cm x 73.7cm x 130.2cm (44 in x 29 in x 51.25 in)
Weight 366 kg (807 lb)
Line voltage Dedicated, single-phase AC power line
North America: 120 V AC
Continental Europe: 200–240 V AC
Line frequency North America: 50–60 Hz
Continental Europe: 50–60 Hz
Average heat output 4100 BTUs per hour
Operating temperature 15°–30°C (59°–86°F)
Ambient relative humidity 15%–75% RH noncondensing
Altitude -0.1524/2.439 km (-500/8000 ft)
Plumbing No water or drain required; self-contained onboard waste management eliminates special requirements for offboard plumbing
Reagents No preparation, no mixing or reconstitution required for Integrated Reagent Packs, Signal Reagent, and Universal Wash Reagent
Onboard test capacity Up to 2,000 assays
Up to 20 different Integrated Reagent Packs (100 assays each; resident on-board simultaneously; automatic, self-contained, temperature and humidity controlled Reagent Supply)
Calibration Multiple lots may be precalibrated with automatic lot switching
Up to 28 days
Process: Random Access Calibration with Automatic Result Protection; 25 calibrations across 16 lots per assay
Throughput Up to 90 reportable patient results per hour
Sample capacity 60 samples in universal trays
Universal sample trays Accomodate 5mL, 7mL, and 10mL collection tubes; 1.5mL microcollection containers; VITROS® microsample cups and 0.5mL and 2.0mL cups
Laboratory Information System (LIS) Bidirectional interface for ASTM and Kermit protocols
Broadcast download 4 RS 232 serial ports

 

| ผลิตภัณฑ์ในกลุ่ม